Tvs Diode Array Spa Diodes Page 19 TVS Diode Array SPA Diodes Catalog

2017 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 02/23/17 TVS Diode Arrays (SPA Diodes) General Purpose ESD Protection - SP720 Series Time Temperature T P T L T S(max) T S(min) 25 t P t L t S time to peak temperature Preheat Ramp-up Ramp-down Ramp-do Critical Zone TL to T P Critical Zone TL to T P Reflow Condition Pb - Free assembly Pre Heat - Temperature Min (T s(min) ) 150C - Temperature Max (T s(max) ) 200C - Time (min to max) (t s ) 60 - 180 secs Average ramp up rate (Liquidus) Temp (T L ) to peak 5C/second max T S(max) to T L - Ramp-up Rate 5C/second max Reflow - Temperature (T L ) (Liquidus) 217C - Temperature (t L ) 60 - 150 seconds Peak Temperature (T P ) 260 +0/-5 C Time within 5C of actual peak Temperature (t p ) 20 - 40 seconds Ramp-down Rate 5C/second max Time 25C to peak Temperature (T P ) 8 minutes Max. Do not exceed 260C Soldering Parameters C L E e A C e B e C -B- E1 INDEX 1 2 3 N/2 N AREA SEATING BASE PLANE -C- D1 B1 B e D D1 A A2 L A1 -A- 0.010 (0.25) C A M B S Package PDIP Pins 16 Lead Dual-in-Line JEDEC MS-001 Millimeters Inches Notes Min Max Min Max A - 5.33 - 0.210 4 A1 0.39 - 0.015 - 4 A2 2.93 4.95 0.115 0.195 - B 0.356 0.558 0.014 0.022 - B1 1.15 1.77 0.045 0.070 8, 10 C 0.204 0.355 0.008 0.014 - D 18.66 19.68 0.735 0.775 5 D1 0.13 - 0.005 - 5 E 7.62 8.25 0.300 0.325 6 E1 6.10 7.11 0.240 0.280 5 e 2.54 BSC 0.100 BSC - e A 7.62 BSC 0.300 BSC 6 e B - 10.92 - 0.430 7 L 2.93 3.81 0.115 0.150 4 N 16 9 Notes: 1. Controlling Dimensions: INCH. in case of conflict between English and Metric dimensions, the inch dimensions control. 2. Dimensioning and tolerancing per ANSI Y14.5M-1982. 3. Symbols are defined in the "MO Series Symbol List" in Section 2.2 of Publication No. 95. 4. Dimensions A, A1 and L are measured with the package seated in JE-DEC seating plane gauge GS-3. 5. D, D1, and E1 dimensions do not include mold flash or protrusions. Mold flash or protrusions shall not exceed 0.010 inch (0.25mm). 6. E and e A are measured with the leads constrained to be perpendicular to datum -C- . 7. e B and e C are measured at the lead tips with the leads unconstrained. e C must be zero or greater. 8. B1 maximum dimensions do not include dambar protrusions. Dambar protrusions shall not exceed 0.010 inch (0.25mm). 9. N is the maximum number of terminal positions. 10. Corner leads (1, N, N/2 and N/2 + 1) for E8.3, E16.3, E18.3, E28.3, E42.6 will have a B1 dimension of 0.030 - 0.045 inch (0.76 - 1.14mm). Package Dimensions Dual-In-Line Plastic Packages (PDIP)

Previous Page
Next Page