Sensors Products Page 9 Reed Sensors

9 Product Series Description Overall Dimensions Contact Rating Switching Voltage Breakdown Voltage Switching Current Contact Resistance, Initial Mating Actuator mm (inch) W Vdc A Ohms Thread Pitch x L Max. Min. Max. 59060 Stainless Steel Threaded Barrel Sensor, Normally Open M8 x 1.25 Pitch x 36.00 (1.420) 10 200 250 0.5 0.2 57060 Stainless Steel Threaded Barrel Sensor, Normally Open High Voltage M8 x 1.25 Pitch x 36.00 (1.420) 10 300 450 0.5 0.2 Stainless Steel Threaded Barrel Sensor, Changeover M8 x 1.25 Pitch x 36.00 (1.420) 5 175 200 0.25 0.2 Stainless Steel Threaded Barrel Sensor, Normally Closed M8 x 1.25 Pitch x 36.00 (1.420) 5 175 200 0.25 0.2 59065 Threaded Barrel Sensor (Standard), Normally Open (5/16 x 24) Pitch x 38.10 (1.500) 10 200 250 0.5 0.2 57065 Threaded Barrel Sensor (Standard), Normally Open High Voltage (5/16 x 24) Pitch x 38.10 (1.500) 10 300 450 0.5 0.2 Threaded Barrel Sensor (Standard), Changeover (5/16 x 24) Pitch x 38.10 (1.500) 5 175 200 0.25 0.2 Threaded Barrel Sensor (Standard), Normally Closed (5/16 x 24) Pitch x 38.10 (1.500) 5 175 200 0.25 0.2 59070 Threaded Barrel Sensor (Metric), Normally Open M8 x 1.25mm Pitch x 38.10 (1.500) 10 200 250 0.5 0.2 57070 Threaded Barrel Sensor (Metric), Normally Open High Voltage M8 x 1.25mm Pitch x 38.10 (1.500) 10 300 450 0.5 0.2 Threaded Barrel Sensor (Metric), Changeover M8 x 1.25mm Pitch x 38.10 (1.500) 5 175 200 0.25 0.2 Threaded Barrel Sensor (Metric), Normally Closed M8 x 1.25mm Pitch x 38.10 (1.500) 5 175 200 0.25 0.2 59075 Heavy Duty Threaded Barrel, Normally Open M12 x 1mm Pitch x 46.00 (1.810) 10 200 250 0.5 0.2 57075 Heavy Duty Threaded Barrel, Normally Open High Voltage M12 x 1mm Pitch x 46.00 (1.810) 10 300 450 0.5 0.2 Heavy Duty Threaded Barrel, Changeover M12 x 1mm Pitch x 46.00 (1.810) 5 175 200 0.25 0.2 Heavy Duty Threaded Barrel, Normally Closed M12 x 1mm Pitch x 46.00 (1.810) 5 175 200 0.25 0.2 Product Series Description Overall Dimensions Contact Rating Switching Voltage Breakdown Voltage Switching Current Contact Resistance, Initial Mating Actuator mm (inch) W Vdc A Ohms L X W X H Max. Min. Max. 59105 Terminal Flange Mount Sensor, Normally Open 40.17 (1.582) x 19.05 (0.750) x 6.60 (0.260) 10 200 250 0.5 0.2 57105 Terminal Flange Mount Sensor, Normally Open High Voltage 40.17 (1.582) x 19.05 (0.750) x 6.60 (0.260) 10 300 450 0.5 0.2 Terminal Flange Mount Sensor, Normally Closed 40.17 (1.582) x 19.05 (0.750) x 6.60 (0.260) 5 175 200 0.25 0.2 59125 Pinned Flange Mount Sensor, Normally Open 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 10 200 250 0.5 0.2 57125 Pinned Flange Mount Sensor, Normally Open High Voltage 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 10 300 450 0.5 0.2 Pinned Flange Mount Sensor, Normally Closed 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 5 175 200 0.25 0.2 59135 High-Temp Flange Mount Sensor, Normally Open 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 10 200 250 0.5 0.2 57135 High-Temp Flange Mount Sensor, Normally Open High Voltage 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 10 300 450 0.5 0.2 High-Temp Flange Mount Sensor, Changeover 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 5 175 200 0.25 0.2 High-Temp Flange Mount Sensor, Normally Closed 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 5 175 200 0.25 0.2 59140 Mini Flange Mount Sensor, Normally Open 23.0 (0.906) x 14.00 (0.551) x 6.00 (0.236) 10 200 250 0.5 0.2 57140 Mini Flange Mount Sensor, Normally Open High Voltage 23.0 (0.906) x 14.00 (0.551) x 6.00 (0.236) 10 300 450 0.5 0.2 Mini Flange Mount Sensor, Changeover 23.0 (0.906) x 14.00 (0.551) x 6.00 (0.236) 5 175 200 0.25 0.2 Mini Flange Mount Sensor, Normally Closed 23.0 (0.906) x 14.00 (0.551) x 6.00 (0.236) 5 175 200 0.25 0.2 59141 Mini Flange Mount Sensor, Normally Open 23.0 (0.906) x 14.00 (0.551) x 6.00 (0.236) 10 200 250 0.5 0.2 57140 Mini Flange Mount Sensor, Normally Open High Voltage 23.0 (0.906) x 14.00 (0.551) x 6.00 (0.236) 10 300 450 0.5 0.2 Mini Flange Mount Sensor, Changeover 23.0 (0.906) x 14.00 (0.551) x 6.00 (0.236) 5 175 200 0.25 0.2 Mini Flange Mount Sensor, Normally Closed 23.0 (0.906) x 14.00 (0.551) x 6.00 (0.236) 5 175 200 0.25 0.2 59145 Flange Mount Sensor, Normally Open 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 10 200 250 0.5 0.2 57145 Flange Mount Sensor, Normally Open High Voltage 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 10 300 450 0.5 0.2 Flange Mount Sensor, Changeover 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 5 175 200 0.25 0.2 Flange Mount Sensor, Normally Closed 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 5 175 200 0.25 0.2 59150 Flange Mount Sensor, Normally Open 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 10 200 250 0.5 0.2 57150 Flange Mount Sensor, Normally Open High Voltage 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 10 300 450 0.5 0.2 Flange Mount Sensor, Changeover 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 5 175 200 0.25 0.2 Flange Mount Sensor, Normally Closed 28.57 (1.125) x 19.05 (0.750) x 6.35 (0.250) 5 175 200 0.25 0.2 THREADED BARREL Designed with a cylindrical package, this sensor is available with English and metric threads. It may easily be mounted and adjusted using the supplied retaining nuts. FLANGE/FLAT PACK This sensor offers a rectangular package that is designed for mounting on a flat surface. It is suitable for use in a wide range of environments, including high-temperature applications. Product Series Description Overall Dimensions Contact Rating Switching Voltage Breakdown Voltage Switching Current Contact Resistance, Initial mm (inch) W Vdc A Ohms L x W x H Max. Min. Max. 59210 Lever Arm Sensor 24 (0.945) x 23 (0.906) x 10 (0.394) 10 200 250 0.5 0.2 LEVER ARM This clip frame sensor with a lever arm is ideally suited for paper-path sensing and security system applications. hamlin.com littelfuse.com

Previous Page
Next Page